Problem Description

There are SNMP OIDs for each sensor on the ProxySG. 
What are those OIDs?

Resolution

Here is a list of sensors and the SNMP OID for that sensor:

Sensor Name SNMP OID
Motherboard temperature 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.1
Power supply cage temperature 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.2
CPU 1 temperature 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.3
Fan 1 speed 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.4
Fan 2 speed 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.5
Fan 3 speed 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.6
Power supply 1 fan 1 status 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.7
Power supply 1 fan 2 status 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.8
Power supply 2 fan 1 status 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.9
Power supply 2 fan 2 status 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.10
CPU 1 fan speed 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.11
+3.3V bus voltage 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.12
+5V bus voltage 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.13
+12V bus voltage 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.14
CPU 1 core voltage 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.15
CPU 1 +2.6V bus voltage 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.16
Power supply 1 status 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.17
Power supply 2 status 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.18

(Note:  The above sensors come from an 8100-B, but they should be the same for most platforms)

The easiest way to verify any of the OIDs above is to use the SNMP get command and then verify the sensor reading in the sysinfo.  For example, here is a reading of the OID (with public configured as the community string) and the sensor output from a sysinfo:

Host> snmpget -c public -v2c <ProxySG IP> 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.1
SNMPv2-SMI::enterprises.3417.2.1.1.1.1.1.5.1 = INTEGER: 238

From the sysinfo:

Hardware sensors
URL_Path /Sensors/Current
; Sensor statistics

; Sensor name       Reading           Status
;-----------------------------------------------------
Motherboard temperature            23.8 C            OK             
Power supply cage temperature      19.8 C            OK             
CPU 1 temperature                  38.7 C            OK             
Fan 1 speed                        3883.5 RPM        OK             
Fan 2 speed                        3870.7 RPM        OK             
Fan 3 speed                        3834.4 RPM        OK             
Power supply 1 fan 1 status                          OK             
Power supply 1 fan 2 status                          OK             
Power supply 2 fan 1 status                          FAN STOPPED    
Power supply 2 fan 2 status                          FAN STOPPED    
CPU 1 fan speed                    6186.5 RPM        OK             
+3.3V bus voltage                  3.33 volts        OK             
+5V bus voltage                    5.12 volts        OK             
+12V bus voltage                   12.21 volts       OK             
CPU 1 core voltage                 1.47 volts        OK             
CPU 1 +2.6V bus voltage            2.59 volts        OK             
Power supply 1 status                                OK             
Power supply 2 status                                NO POWER       

Notice the value is 238 from the SNMP command which matches 23.8C as the motherboard temperature.
 

The OID values could change for newer platforms.  In that case you should be able to match the sensor readings from the sysinfo and the output of the snmpget command with OID 1.3.6.1.4.1.3417.2.1.1.1.1.1.5.x (where "x" is 1, 2, 3, 4, and so forth).


Rate this Page

Please take a moment to complete this form to help us better serve you.

Did this document help answer your question?
 
 
If you are finished providing feedback, please click the RATE CONTENT button. Otherwise, please add more detail in the following text box and then click RATE CONTENT.
 
 

Your response will be used to improve our document content.

Ask a Question