Solutions

Session Monitor bin cannot be synchronized after the Session Monitor service or proxy is restarted

Solutions ID:    KB5041
Version:    4.0
Status:    Published
Published date:    04/02/2012
Updated:    10/08/2013
 

Problem Description

Session Monitor bin cannot be synchronized after the Session Monitor service or proxy is restarted.

The following errors are reported in the session monitor log: "Error parsing incoming bin entry during bin transfer", and "invalid IP address type".

Resolution

This defect, B#175124, was fixed :

- SG 6.2.8.3

- SG 6.2.9.1 and newer SG 6.2.x versions

- SG 6.3.3.1 and newer SG 6.3.x versions

 

SG 6.4 and newer SG 6.x versions are not affected by this.