Problem Description

You need to deploy the ThreatPulse Client Connector executable without requiring end user interaction.

This may be necessary for scripted installs or deployment through a centralized management system (e.g. Microsoft SCCM or others)

 

Resolution

Here are the commands that can be used from a script or an administrative command prompt to quietly install the Client Connector:

 

To install:

msiexec /i ClientInstaller.msi /quiet /norestart

 

To uninstall

msiexec /x ClientInstaller.msi /quiet /norestart

 

NOTE: If necessary, the installer password can be added to the command line as usual by appending "SUP=mypassword" behind the name of the MSI file. 

See the following article for more information on the install/uninstall password: KB4840

 

 

The /norestart switch is recommended to minimize end user interruption.

A restart is actually required to fully complete the installation and uninstallation and the Client Connector may not function properly until the operating system has been rebooted.

Either the /promptrestart or the /restart switches will cause the operating system to reboot at the end of the installation without warning or confirmation.

 

NOTE: This article only applies to installing the Client Connector on the Microsoft Windows operating system.

 


Rate this Page

Please take a moment to complete this form to help us better serve you.

Did this document help answer your question?
 
 
If you are finished providing feedback, please click the RATE CONTENT button. Otherwise, please add more detail in the following text box and then click RATE CONTENT.
 
 

Your response will be used to improve our document content.

Ask a Question